CUET-PG SERIES
Chemical-thermal-and-polymer-engineering

Biochemical Engineering

11 previous year questions.

Volume: 11 Ques
Yield: Medium

High-Yield Trend

11
2024

Chapter Questions
11 MCQs

01
PYQ 2024
medium
chemical-thermal-and-polymer-engineering ID: cuet-pg-
Dynamic response of a system consists of:
A. steady state response only
B. transient state response only
C. unsteady state response only
D. non-transient state response only
1
A and B only
2
A and D only
3
C and D only
4
B and C only
02
PYQ 2024
medium
chemical-thermal-and-polymer-engineering ID: cuet-pg-
Microprocessor-based systems which are increasingly being used for dedicated applications in process instrumentation are:
1
Intelligent instrumentation systems
2
Dumb instrumentation systems
3
Control instrumentation systems
4
Robust instrumentation systems
03
PYQ 2024
medium
chemical-thermal-and-polymer-engineering ID: cuet-pg-
The lower limit of the useful working range of a transducer is determined by its:
A. error
B. noise
C. accuracy
D. stability
1
A and B only
2
A and C only
3
B and C only
4
B and D only
04
PYQ 2024
medium
chemical-thermal-and-polymer-engineering ID: cuet-pg-
Routh test criterion:
A is applicable only to those systems with polynomial characterizatic equation
B. does not prove any information about the actual location of roots
C. is applicable only to those systems with non-polynomial characterizatic equation
D. Gives full information about the actual location of roots
1
A and B Only
2
C and D Only
3
B and C Only
4
A and D Only
05
PYQ 2024
medium
chemical-thermal-and-polymer-engineering ID: cuet-pg-
When the damping coefficient is equal to 1 for a second-order system, then
A. both the roots will be equal
B. both the roots will be real
C. both the roots will be complex
D. both the roots will be unequal
1
A and B Only
2
B and C Only
3
C and D Only
4
A and D Only
06
PYQ 2024
medium
chemical-thermal-and-polymer-engineering ID: cuet-pg-

Match List-I with List-II:

List-IList-II
(A) A device whose output is an enlarged version of input(I) Amplifier
(B) The process of making adjustments so that the instrument readings conform to accepted standards(II) Calibration
(C) Measures and generates an opposing effect to maintain zero deflection(III) Null type detector
(D) An action to convey information(IV) Signal
1
A-III, B-II, C-IV, D-I
2
A-I, B-I, C-IV, D-III
3
A-III, B-IV, C-I, D-II
4
A-II, B-I, C-III, D-IV
07
PYQ 2024
medium
chemical-thermal-and-polymer-engineering ID: cuet-pg-
In a closed-loop system, the process to be controlled is an integrating process with a transfer function . The controller proposed to be used is an integral controller with transfer function . When a step change in the set point is applied to such a closed system, the controlled variable will exhibit:
1
Overdamped response
2
Underdamped response
3
Undamped response
4
Unstable response
08
PYQ 2024
medium
chemical-thermal-and-polymer-engineering ID: cuet-pg-
The first-order thermometer used has a time constant of 50 s. If it is subjected to a sinusoidal input cycling at 0.002 Hz, then the time lag produced in the instrument will be:
1
0.0025 s
2
0.001 s
3
0.002 s
4
0.004 s
09
PYQ 2024
medium
chemical-thermal-and-polymer-engineering ID: cuet-pg-
Routh test cannot be used to test the stability of a control system containing:
1
Controller
2
Transportation lag
3
Final control element
4
Controller and control element
10
PYQ 2024
medium
chemical-thermal-and-polymer-engineering ID: cuet-pg-
Industrial paddle agitators turn at speed between:
1
20–100 rpm
2
200–400 rpm
3
650–850 rpm
4
2000–2500 rpm
11
PYQ 2024
medium
chemical-thermal-and-polymer-engineering ID: cuet-pg-
Impeller diameter in the case of a turbine agitator is:
1
5
2
30-50
3
60-75
4
Specification not required